Harris Fluke Networks 19800-003 TS19 Series Butt-in Telephone Test Set with Banana Jacks to Alligator Clips
Butt-in Telephone Test
Set
Harris Fluke Networks 19800-003 (TS-19
19800003)
TS19 Series with Banana Jacks to
Alligator Clips
TSTR-BUTT-TS19800003

Butt-in
Telephone Test Set
Harris
Fluke Networks 19800-003 (TS-19 19800003)
TS19 Series with Banana Jacks to Alligator Clips
TS®19 Test Set
Specifically designed for in-house telecom
technicians, the TS®19 Test Set combines all the basic test set features at a
value price - plus it provides DataSafe™ protection to prevent accidental
disruption of data service in monitor mode.
Features:
>
High-impedance DataSafe™ operation in monitor mode
> Tone (DTMF) and pulse
operation
> Last number redial
> Polarity indication in talk
mode
The Fluke Networks TS19 Test Set combines all the essential test set
features at a value price. This test set was specifically designed for in-house
telecom technicians. Its high-impedance monitor prevents accidental disruption
of service from clipping onto a data line while in monitor mode, thus ensuring
the integrity of critical data lines. Features such as tone (DTMF) or pulse
operation, talk/monitor capabilities, polarity test button and last number
redial make this test set the perfect combination of features and
price.
Specifications (TS-19 Series):
Electrical
>
Loop Limit: 2.4 kO
maximum at 48 VDC (nominal 15 mA minimum loopcurrent)
> DC Resistance
(Talk Mode): 150 O typical at 80 mA current
> AC Impedance (Monitor Mode):
Low impedance (Ring position) 600 O at 1 KHz
typical
High impedance (HI Z position) 100 kO minimum at 1
KHz
> Rotary Dial Output: 10 pps .5 pps
> Pulsing Rate: 60 % ± 2
%
> Percent Break: 800 ms typical
> Interdigit Interval Leakage
During Break: > 50 kO
> DTMF Output: ±1 % maximum
> Tone
Frequency Error Level per Tone Pair: dBm maximum, - dBm minimum
> High
versus Low Tone Difference: 4 dB maximum
Physical
> Length: 8.75 in (22.2 cm)
> Width: 2.375 in (6.03
cm)
> Height: 3.375 in (8.57 cm)
> Weight: 10.8 oz (.307 kg)
maximum
Environmental
>
Temperature:
Operating: -5 °C to °C
Storage:
-40 °C to °C
> Drop: 1 meter, 4 times
> Altitude: To 3,000 meters
(10,000 feet) maximum
> Relative Humidity: 10 %to 80 %
(non-condensing)
> Regulatory Standards Used:
47 CFR Part
15, Subpart B
ICES-003 Issue 3
AS/NZS
3548
EMC Directive 89/336/EEC, EN 55022:98, EN 61326:97, A1:98
Annex C, EN 61000-4-2, EN 61000-4-3
LV Directive 73/23/EEC, EN
610010.1 (1993)
Certifications and Compliance
> Conformité
Européenne. Conforms to relevant European Union directives.
>
CAN/CSA-C22.2 No. 60950-1-03
> CAN/CSA-C22.2 No. 1010.1-92 CSA-C22.2 No.
1010.1B-97, UL/ANSI 3111-1
Notes:
Specifications subject to change
without notice. Legal requirements may exist regarding permission to connect
equipment to a Telecom network operated by a public network operator.
www.flukenetworks.com
you may also be interested in . . .
| Also in the Harris Fluke Networks 19800-003 TS19 Series Butt-in Telephone Test Set with Banana Jacks to Alligator Clips category... |




